This
laboratory provides a full set simulated round-the-clock ambient
test conditions for the room comfort air conditioning manufacturers
and according its outside simulated conditions, such as
sunshine, rain, snow
and air blowing
etc. to test the
products work capability and performances.
■SPECIFICATION:
※Main test
items:
The cold capability and
lasting characters of the air conditioner in high temperature at
the outside door, the heat capability of the heat
pump in low temperature at the outside door, the defrost
performance and lasting
characters.

※Test range:
Cold volume
2500w~15000w
※Test
range of the room temperature and humidity:
Outside door: -20℃~60℃,40%~95%RH
Inside door: 20℃~35℃,40%~90%RH
※Precision:
Temperature:
±2℃, humidity: ±5%RH
※Test control method:
PC auto-control system with manual switch.